Fluke 1623-2地面测试仪-上海麒诺机电
Fluke 1623-2和1625-2 GEO地面测试仪
GEO地面测试仪
新型Fluke 1623-2和
1625-2 GEO Earth Ground
测试人员提供数据存储
和下载功能
通过USB端口。世界级
配件将简化
并加快测试时间。
产品特点:
•3极和4极电势下降,
接地回路测试
•4极土壤电阻率测试
•选择性接地棒
使用1个夹具进行测试
•无桩接地棒
使用2个夹具进行测试
•IP56额定用于室外
•专业手提箱
•USB数据存储和传输
General
Display:1999 digit LCD Display with special symbols, digit height 25 mm
User interface Instant measurement through TURN and START one button concept. The only operating elements
are rotary switch and START button
Robust, water and dust resistant Instrument is designed for tough environmental conditions (rubber protective cover, IP56)
Memory Internal memory storage up to 1500 records accessible via USB port
Temperature ranges
Operating temperature -10 °C to 50 °C (14 °F to 122 °F)
Storage temperature -30 °C to +60 °C (-22 °F to +140 °F)
Temperature coefficient ± 0.1 % of reading/°C <18 °C >28 °C
Intrinsic error Refers to the reference temperature range and is guaranteed for 1 year
Operating error Refers to the operating temperature range and is guaranteed for 1 year
Climatic class C1 (IEC 654-1), -5 °C to +45 °C (23° to +115° F), 5 % to 95 % RH
Protective type IP56 for case, IP40 for battery door according to EN60529
Safety Protection by double and/or reinforced insulation. max. 50 V to earth. IEC61010-1: CAT none,
Pollution degree 2
EMC (Emission Immunity) IEC61326-1: Portable
Quality system Developed, designed and manufactured according to DIN ISO 9001
External voltage V ext, max = 24 V (dc, ac < 400 Hz), measurement inhibited for higher values
V ext rejection > 120 dB (162⁄3, 50, 60, 400 Hz)
Measuring time Typical 6 sec.
Max. overload 250 V rms (pertains to misuse)
Auxiliary power 6 x 1.5 V alkaline (type AA LR6)
Battery life span Typical > 3,000 measurements
Dimensions (WxHxD) 250 mm x 133 mm x 187 mm (9.75 in x 5.25 in x 7.35 in)
Weight 1.1 kg (2.43 lb) including batteries